PS-02 Redundancy Model

5 sub-criteria: 3 basic, 2 additional, with customer criteria

Changed since C5:2020

Basic criterion

Specified that the two locations should provide each other with resilience as well.

Modified requirement for checking the functionality to be for checking the effectiveness of the redundancy.

Additional criterion

Removed requirement for checking the effectiveness of the redundancy, as this is, with the new way criteria are structure in C5:2026, already covered by the basic criterion.

Wording in C5:2020

Basic criterion

The cloud service is provided from two locations that are redundant to each other. The locations meet the security requirements of the Cloud Service Provider (cf. PS-01 Security Concept) and are located in an adequate distance to each other to achieve operational redundancy. Operational redundancy is designed in a way that ensures that the availability requirements specified in the service level agreement are met. The functionality of the redundancy is checked at least annually by suitable tests and exercises (cf. BCM-04 - Verification, updating and testing of business continuity).

Additional criterion

The cloud service is provided from more than two locations that provide each other with redundancy. The locations are sufficiently far apart to achieve georedundancy. If two locations fail at the same time, at least one third location is still available to prevent a total service failure. The georedundancy is designed in a way that ensures that the availability requirements specified in the service level agreement are met.. The functionality of the redundancy is checked at least annually by suitable tests and exercises (cf. BCM-04 - Verification, updating and testing of business continuity).

All changes since C5:2020

Basic criterion

PS-02.01B

The cloud service is provided from at least two locations. The locations meet the security requirements of the cloud service provider (cf. PS-01) and are located in an adequate distance to each other to achieve operational redundancy and resilience.

Supplementary information

Also applies to 02B

Operational redundancy of the sites to each other in the sense of this criterion is given if based on the assessment of elementary risks at the site corresponding distances of the premises and buildings to these risks are maintained. Very extensive events which, due to their extent, could affect several sites of the same redundancy group simultaneously or in a timely manner (e.g. floods, earthquakes) are not considered.

There are cloud service providers who no longer address the issue of reliability of the cloud service on a physical level through redundancy from two independent locations, but through resilience. The cloud service is provided simultaneously from more than two locations. The underlying distributed data centre architecture ensures that the failure of a location or components of a location does not violate the defined availability criteria of the cloud service. Such an architecture can represent an alternative fulfilment (cf. Chapter 3.4.12) of the criterion. The tests and exercises on functionality required in the criterion also apply analogously to resilient architectures.

PS-02.02B

Operational redundancy is designed in a way that ensures that the availability requirements specified in the service level agreement are met.

Supplementary information

Also applies to 01B

Operational redundancy of the sites to each other in the sense of this criterion is given if based on the assessment of elementary risks at the site corresponding distances of the premises and buildings to these risks are maintained. Very extensive events which, due to their extent, could affect several sites of the same redundancy group simultaneously or in a timely manner (e.g. floods, earthquakes) are not considered.

There are cloud service providers who no longer address the issue of reliability of the cloud service on a physical level through redundancy from two independent locations, but through resilience. The cloud service is provided simultaneously from more than two locations. The underlying distributed data centre architecture ensures that the failure of a location or components of a location does not violate the defined availability criteria of the cloud service. Such an architecture can represent an alternative fulfilment (cf. Chapter 3.4.12) of the criterion. The tests and exercises on functionality required in the criterion also apply analogously to resilient architectures.

PS-02.03B

The effectiveness of the redundancy is checked at least annually by suitable tests and exercises (cf. BCM-04).

Additional criterion

PS-02.01AS

Additional, sharpens01B

The cloud service is provided from more than two locations. The locations meet the security requirements of the cloud service provider (cf. PS-01) and are located sufficiently far apart to achieve georedundancy and resilience. If two locations fail at the same time, at least one third location is still available to prevent a total service failure.

Supplementary information

Also applies to 02AS

A georedundancy of the sites to each other in the sense of this criterion is given if a very extensive event at a site under no circumstances affects several sites of the same redundancy group simultaneously or promptly. The BSI publication 'Kriterien für die Standortwahl von Rechenzentren' (German for: 'Criteria for selecting the location of data centres', document only available in German) provides recommendations in this regard.

PS-02.02AS

Additional, sharpens02B

The georedundancy is designed in a way that ensures that the availability requirements specified in the service level agreement are met.

Supplementary information

Also applies to 01AS

A georedundancy of the sites to each other in the sense of this criterion is given if a very extensive event at a site under no circumstances affects several sites of the same redundancy group simultaneously or promptly. The BSI publication 'Kriterien für die Standortwahl von Rechenzentren' (German for: 'Criteria for selecting the location of data centres', document only available in German) provides recommendations in this regard.

Complementary customer criteria

What cloud service customers implement on their side.

Cloud service customers ensure with suitable controls that the existing redundancy model of the cloud service provider and the evidence for the verification of the model comply with their own requirements for the availability and reliability of the cloud service.

All customer criteria in one place